Implement the solution or escalate.
Perform a root cause analysis.
Establish a plan of action to resolve the problem.
Verify full system functionality and if applicable implement preventative measures.
第1题:
When an administrator is troubleshooting a system, which of the following describes the NEXT course of action if a change does not solve the problem?()
第2题:
After installing a second processor and corresponding heatsink into a server, an administrator notices that the new processor is not showing up during POST. Which of the following could be the cause of this issue?()
第3题:
A technician is replacing a processor in a workstation. After installation, the workstation starts up and immediately shuts down; the technician tries to start the workstation several more times and gets the same result. Which of the following is the cause of this issue?()
第4题:
After an HACMP migration, which included a large number of shared disks,cluster testing is performed. During testing, it becomes apparent that Fast Disk Takeover is not working properly. Which of the following is the most likely cause of the problem?()
第5题:
You are maintaining your database in Oracle10g. You want to store the information about the backup of the database in the control file. You issue the following statement: SQL>ALTER SYSTEM SET CONTROL_FILE_RECORD_KEEP_TIME=400; What is the outcome of this statement? ()
第6题:
Create an action plan
Implement and test a solution
Determine if anything has changed
Identity a probable cause
第7题:
DNS is not working properly
Ping is not working properly
The cables are disconnected
The device driver did not load properly
第8题:
第9题:
Document the process and update the baseline.
Test the theory of probable cause and verify with the software vendor.
Establish a plan of action to be included in the business impact analysis.
Implement the software manufacturer workaround.
第10题:
The power supply is not sufficient to power the server.
The voltage regulator module (VRM) was not installed.
The IRQ setting was not set.
The DMA setting was not set.
第11题:
Identify the problem.
Verify full system functionality.
Document all findings.
Establish a theory of probable cause.
第12题:
第13题:
A customer asks the technician for an explanation of the cause of a printer issue, after the issue is resolved. Which of the following would be the MOST appropriate response?()
第14题:
After successfully testing a probable cause to an issue, which of the following is the NEXT troubleshooting step?()
第15题:
Which of the following should be completed NEXT, after testing the theory of probable cause?()
第16题:
An adapter state does not show available after a reboot. Which of the following is the most probable cause?()
第17题:
insufficient speed
cavitation
excess discharge pressure
excessive net positive suction head B
第18题:
The statement will not execute successfully.
The statement will execute successfully, and the backups metadata will be maintained in the control file for 400 days
The statement will execute successfully, and the backups metadata will be maintained in the recovery catalog for 400 days.
Backups will be deleted from the media after 400 days.
第19题:
loss of field excitation
total loss of load
large increase in load
loss of steam pressure
第20题:
The IP addresses are configured incorrectly.
Frame Relay LMI messages not displayed in real time.
The administrator must issue the enable frame-relay lmi debug command.
The administrator must issue the terminal monitor command.
Debug messages can only be received once through the console port.
The administrator must issue the show frame-relay lmi vty 0 4 command
第21题:
Test the theory to determine if the solution will correct the issue, list all other possible causes.
Verify full system functionality.
Document the issue; include details regarding findings, actions taken to resolve the issue, and the outcome.
Establish a theory of probable cause based on previous tests and determine next steps toresolve
第22题:
collect all available data on a casualty
recognize normal operation
identify the probable cause of a symptom
isolate the faulty component
第23题:
DLPAR functions are not available for cloned partitions
The new partition has the same node number as the original LPAR
Additional filesets need to be reinstalled after the alt_disk_install cloning
The speed and duplex settings on the Ethernet adapter on the new LPAR is misconfigured
第24题:
low compression
air-bound fuel system
improper spark
change in viscosity