The server was not powered off correctly.
The proper ESD procedures were not used.
The devices were installed in the incorrect sequence.
The devices are incompatible with the system.
第1题:
A system administrator suspects that there were problems with the AIX installation on a pSeries server. Which of the following commands can be used, with the appropriate flags, to view the BOS installation output files?()
第2题:
An administrator installs new IDE drives into the company server. Upon starting the machine, the BIOS does not recognize any of the drives. Which of the following is the MOST likely cause of the problem?()
第3题:
An administrator creates a new directory then shares it on the Windows server. The administrator sets the permissions for everyone to "Modify" but users report they are unable to create or delete documents. Which of the following is the cause?()
第4题:
The administrator has just installed a new memory module into the server. Now, the server is not showing the new memory. Which of the following should the administrator perform FIRST?()
第5题:
An administrator has shut down a server to install additional memory. When the administrator restarts the server after the upgrade, it times out. Which of the following could be the cause of the problem?()
第6题:
You are an enterprise administrator for Cer-tech .com. All the servers on the network run Windows Server2008. The network consists of a Server that has the Windows Server virtualization role service installed.You create a new virtual machine, installed Windows Server 2008 on it, and configure it to use the physicalnetwork card of the host server. After this installation and configuration the virtual machine, you wereunable to access network resources from the virtual machine. Which of the following options would youchoose to ensure that the virtual host can connect to the physical network?()
第7题:
Increase the amount of RAM
Use a lower voltage power supply
Add a hardware firewall
Install redundant NICs
第8题:
The servers memory
The servers RAID controller battery
The servers processor
The servers NIC teaming configuration
第9题:
The administrator forgot to change the share permissions
The users were not part of the “Everyone” built in group
The administrator shared the files but not the folder
“Modify” only allows users to change existing documents
第10题:
The jumpers are not set correctly on the drives.
The power supply is not rated high enough to support the additional drives.
The BIOS is not compatible with the drives.
The drives are not powered on.
第11题:
The hard drives were not plugged into the server correctly.
The controller driver is outdated and needs to be updated from the OEMs website.
The firmware for the server is too old and does not support the new RAID controller card.
The cable from the controller to the hard drive backplane is not connected.
第12题:
The server was not powered off correctly.
The proper ESD procedures were not used.
The devices were installed in the incorrect sequence.
The devices are incompatible with the system.
第13题:
An administrator just installed a new RAID controller card into a server. The firmware is current for the controller card. When the server is powered up the administrator notices that the RAID controller card is not recognized during POST. Which of the following is the cause of the problem?()
第14题:
After a technician came out and installed a new wireless router, one of the wired workstations began having problems connecting to the file server. This is only an intermittent problem. Which of the following actions will the technician MOST likely perform to resolve this problem?()
第15题:
An administrator notes that after a recent power outage, some open files were corrupted on oneaffected file server. Which of the following items should the administrator consider to determine the cause of this corruption?()
第16题:
A technician wants to increase the reliability of a DHCP server. Which of the following components should be installed to increase the server’s uptime on the network?()
第17题:
A technical consultant needs to deploy a Microsoft Windows 2003 server image from a single x336 to five new x336 servers using Remote Deployment Manager (RDM). After installing and configuring RDM and loading the installation image, the consultant wants to deploy the first server. After the new x336 is booted, it is unable to connect to the RDM server. Which of the following is the most likely cause of the problem?()
第18题:
The new server is not PXE-enabled.
The RDM agent is not configured on the RDM server.
The IBM Director agent is not installed on the new server.
A DHCP server is not installed or configured the network.
第19题:
Change the router's SSID
Move the router's location
Check user permissions
Check the cable ends
第20题:
alog
errpt
lscfg
installp
第21题:
The server's memory
The server's RAID controller battery
The server's processor
The server's NIC teaming configuration
第22题:
System reboot
Reseat the memory
Install the latest firmware
Install the latest driver
第23题:
HBA is compatible with the SAN fiber switch.
Update the newly installed server with the latest KVM drivers.
The UPS will continue to perform as expected with the additional load.
Verify the server NIC is compatible with the NAS.
第24题:
Install the MS Loopback adapter on the virtual machine.
Enable the Multipath I/O feature on the host server.
Install Windows Server virtualization Guest Integration Components on the virtual machine.
Install the MS Loopback adapter on the host server.
None of the above